System Configuration<br />

Circuit Breaker (MCCB)<br />

Noise Filter<br />

Electromagnetic Contac<strong>to</strong>r<br />

R<br />

S<br />

T<br />

Cuts off power in the case<br />

of an overload, <strong>to</strong> protect<br />

the power line.<br />

Protects the power line<br />

from external noise, and<br />

from noise generated by<br />

the servo amplifier.<br />

Switches servo power on<br />

and off. Installation of<br />

a surge protec<strong>to</strong>r is required.<br />

Create the protective circuit.<br />

DC Reac<strong>to</strong>r<br />

Suppresses power<br />

harmonics.<br />

Remove the short bar<br />

between DL1-DL2 and<br />

connect this here, when<br />

needed for high frequency<br />

waves.<br />

External Regenerative Resis<strong>to</strong>r<br />

Use as required, such as for<br />

heavy inertial load<br />

operations.<br />

For special operations, such as<br />

high frequency applications that<br />

require greater power<br />

dissipation than that provided by<br />

the servo amplifier’s internal<br />

regenerative resis<strong>to</strong>r.<br />

Remove the short bar between<br />

RB1-RB4 and connect this here.<br />

Brake Power<br />

Required for use when the<br />

servo mo<strong>to</strong>r is equipped<br />

with a brake.<br />