54:<br />
><br />
production & processing<br />
Mechanical scoop belt-sampler<br />
United Marine Aggregates > Greenwich Wharf, London > 0208 305 0978<br />
United Marine Aggregates at Greenwich Wharf carries out<br />
daily routine testing of aggregates being loaded into rail<br />
wagons. To facilitate regular joint sampling with rail-fed<br />
customers, remotely behind safety guarding, a robust pivoted<br />
sampling scoop was designed and installed.<br />
Samples can now be taken from the moving conveyors, by<br />
lowering the scoop (pivoted centrally) into the stream of<br />
moving material, then pivoting the device, thus sliding the<br />
sample down the short integral chute into a sampling bag on<br />
the ground, thereby minimising manual handling. The ease of<br />
use of the finished device has increased customer confidence<br />
in the conformance of the end product.<br />
www.safequarry.<strong>com</strong><br />
on<br />
video<br />
><br />
Preventing burner fuel fires<br />
Tarmac Central > Mancetter Quarry, Warwickshire > 01827 712324<br />
Kevin Alsop, Coating Plant Foreman at Mancetter Quarry has engineered a system to substantially reduce<br />
the risk of coating plant fires due to fuel leaks or in<strong>com</strong>plete <strong>com</strong>bustion.<br />
Based around two (25mm bore) pressurised ball valves – one for the gas oil supply, the other for the<br />
‘reprocessed’ oil supply – these valves (and pipes) are encased in red nylon tubing. 60psi pressure acts<br />
against a spring to keep the valve open to supply fuel to the burner.<br />
If there is a fire, the nylon tubing heats up and bursts, reducing the pressure to atmospheric level which<br />
automatically closes the fuel valves. There are also separate fuel valve leak detectors which can sense the<br />
presence of unburnt fuel on the non-pressure side of the valve. Upon detection, an alarm is raised, thus<br />
preventing the build-up of unburnt fuel in the dryer or bag filter unit.