6.2 - SELF-CALIBRATION<br />
For machine self-calibration proceed as follows:<br />
- Mount any wheel on the shaft, even if not balanced; better still if of an “average” size.<br />
- Preset the exact dimensions of the wheel mounted.( <strong>use</strong> a sized metal wheel 6" x 14" ± 1")<br />
CAUTION!! Presetting of incorrect dimensions would mean that the machine is not correctly calibra<br />
ted, there<strong>for</strong>e all subsequent measurements will be incorrect until a new self-calibration<br />
is per<strong>for</strong>med with the correct dimensions!<br />
- Per<strong>for</strong>m a spin under normal conditions.<br />
- Add 100 g (3.5 oz) on the outside in any position.<br />
- Shift the 100 g. weight from the outside to the inside keeping the<br />
same position.<br />
- Rotate the wheel until to shift the 100 g. weight to the 12 o’clock<br />
position.<br />
END OF SELF-CALIBRATION<br />
HOME<br />
or<br />
CANCELS SELF-CALIBRATION IN ANY PHASE<br />
I 0162 GB - 19