18.06.2014 Views

AGFA d-lab.3 Digital Compact Lab

AGFA d-lab.3 Digital Compact Lab

AGFA d-lab.3 Digital Compact Lab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

General Data and Informations<br />

Repair<br />

Densitometer<br />

Calibration Automatic prior to every measurement to D=0,10 (Y, M, C)<br />

Data rate 1.200 Baud: Print mode / factory-set<br />

(Jumper 1 and 2 not set)<br />

9.600 Baud: Test mode<br />

Interfaces<br />

Connector 3 (data interface acc. to RS232)<br />

Type: Sub-D 9 poles<br />

Jumper settings Jumper position Mode Baud rate<br />

Normal 1.200<br />

Machine selection<br />

Measuring characteristics<br />

Transport speed<br />

Normal: The Jumpers have no impact<br />

on the densitometer function in this<br />

position<br />

Do not set! Only for the assembly !<br />

Densitometer may get damaged<br />

1.200<br />

Selection by means of soldering bridge Br1:<br />

Br1 open<br />

When Br1 is open, the transport speed can be selected with Br2<br />

Measuring range<br />

Reflection D=0,00 to 2,55 (minus the basic density)<br />

Measuring accuracy under the particular climatic conditions<br />

− Linearity, reproducibility:<br />

- to density 1,30 ± D=0,01<br />

- to density 2,00 ± D=0,02<br />

- to density 2,55 ± D=0,03<br />

Selection by means of soldering bridge Br2 (Br1 must be open):<br />

Br2 short-circuited V = 1.400 mm/min d-<strong>lab.3</strong> Process<br />

—<br />

10.6 2000-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!