Repair Maintenance Maintenance Schedule and Maintenance Intervals yearly x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x every 2 years Technician required Entire machine Clean the inner compartments Clean and grease all chains, gears and bearings Scanner Oil the scanner carriage Negative carrier: lubricate the toothed belt and the shafts Negative carrier: clean 2 roller sets Negative mask: lubricate the pawl / the holes in the bearing plate Optical area Clean the lamphouse area Clean the exposure filters Check / replace the mirror Check / replace the prism disk (mirror box) Clean the mirror box inside Clean the paper filter on the scanner carriage Clean the Zoom lens Printer: Transport Unit and Lane Distributor Check / replace the plastic bearings at the motor Check / replace the springs Toothed belt drive: Check / adjust the tension Clean the shifter shafts Clean the side plates Grease the bearing points Clean the rubber rollers Paper Processor, general Clean and grease all chains, gears, bearings Check circulation pumps, replenishing pumps, fans, hose fittings for tight seating/correct functioning Wet section, processing racks Clean the racks, check for smooth movement Check the slide bearings, roller shafts, springs, gears Check the backlash of the spring rollers; if necessary replace the bottom rollers and squeeze rollers Replace all sponge rubber rollers (squeeze area) Clean the bearing points and remove all crystals Lubricate the shaft bearing points Wet section, general Check the replenisher valves and replace them if necessary If required: Replace the circulation pumps Lubricate the mixer of chemistry AGFA d-lab.3 2001-01-02 /PN 9009 9.1
- Page 381 and 382: Printer Repair Sheet Transfer ST, r
- Page 383 and 384: Printer Repair ■ 6.4.64 2001-01-0
- Page 385: Paper Processor Repair ■ 7.ii 200
- Page 389 and 390: Repair Paper Processor Block Circui
- Page 393 and 394: Repair Paper Processor Signal Lists
- Page 395 and 396: Repair Paper Processor Paper Exit P
- Page 397 and 398: Repair Paper Processor Connections
- Page 401 and 402: Repair Paper Processor Functional D
- Page 403 and 404: Repair Paper Processor Electrical S
- Page 405 and 406: Repair Paper Processor Paper Proces
- Page 407 and 408: Repair Paper Processor AC/DC Power
- Page 409 and 410: Repair Paper Processor AC Power Sup
- Page 411 and 412: Repair Paper Processor Densitometer
- Page 415 and 416: Repair Paper Processor Repair Repla
- Page 417 and 418: Repair Paper Processor Replacing Pr
- Page 419 and 420: Repair Paper Processor Temperature
- Page 421 and 422: Repair Software Contents Software S
- Page 425 and 426: Repair Software Software Structure
- Page 427 and 428: Repair Software Software Structure
- Page 429 and 430: Repair Maintenance Contents Mainten
- Page 434 and 435: Maintenance Repair yearly x x x x x
- Page 436 and 437: Maintenance Repair Scanner Oil the
- Page 438 and 439: Maintenance Repair Transport Unit a
- Page 440 and 441: Maintenance Repair After mounting t
- Page 442 and 443: Maintenance Repair Inlet Rollers in
- Page 444 and 445: Maintenance Repair Maintenance Jobs
- Page 446 and 447: Maintenance Repair Lubricants Part
- Page 448: General Data and Information Repair
- Page 452 and 453: General Data and Informations Repai
- Page 454 and 455: General Data and Informations Repai
- Page 456 and 457: General Data and Informations Repai
- Page 458 and 459: General Data and Informations Repai
- Page 460 and 461: General Data and Informations Repai
- Page 462 and 463: General Data and Informations Repai
- Page 464 and 465: Index Repair L (cont.) Laser Fundam
- Page 466: Index Repair ■ 11.4 2001-01-02 /P
Repair<br />
Maintenance<br />
Maintenance Schedule and Maintenance Intervals<br />
yearly<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
every<br />
2 years<br />
Technician required<br />
Entire machine<br />
Clean the inner compartments<br />
Clean and grease all chains, gears and bearings<br />
Scanner<br />
Oil the scanner carriage<br />
Negative carrier: lubricate the toothed belt and the shafts<br />
Negative carrier: clean 2 roller sets<br />
Negative mask: lubricate the pawl / the holes in the bearing plate<br />
Optical area<br />
Clean the lamphouse area<br />
Clean the exposure filters<br />
Check / replace the mirror<br />
Check / replace the prism disk (mirror box)<br />
Clean the mirror box inside<br />
Clean the paper filter on the scanner carriage<br />
Clean the Zoom lens<br />
Printer: Transport Unit and Lane Distributor<br />
Check / replace the plastic bearings at the motor<br />
Check / replace the springs<br />
Toothed belt drive: Check / adjust the tension<br />
Clean the shifter shafts<br />
Clean the side plates<br />
Grease the bearing points<br />
Clean the rubber rollers<br />
Paper Processor, general<br />
Clean and grease all chains, gears, bearings<br />
Check circulation pumps, replenishing pumps, fans, hose fittings for tight<br />
seating/correct functioning<br />
Wet section, processing racks<br />
Clean the racks, check for smooth movement<br />
Check the slide bearings, roller shafts, springs, gears<br />
Check the backlash of the spring rollers;<br />
if necessary replace the bottom rollers and squeeze rollers<br />
Replace all sponge rubber rollers (squeeze area)<br />
Clean the bearing points and remove all crystals<br />
Lubricate the shaft bearing points<br />
Wet section, general<br />
Check the replenisher valves and replace them if necessary<br />
If required: Replace the circulation pumps<br />
Lubricate the mixer of chemistry<br />
<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 9.1