Repair<br />

Paper Processor<br />

AC/DC Power Supply<br />

1 Cover Paper Processor control<br />

2 Main switch<br />

3 RCD device<br />

4 AC power supply<br />

5 DC power supply<br />

6 Remove screws to open the cover<br />

dlabr165<br />

If necessary, the AC and DC power supply can be<br />

removed separately.<br />

DC Power Supply<br />

1 Power supply PS1<br />

- 24 V Power supply Scanner<br />

- 5 V Main power supply Printer<br />

- 5,2 V Densitometer power supply -<br />

24 V / 8 V Pilot power supply (Timer)<br />

2 55A-PWD<br />

dlabr166<br />

55A-PWD<br />

LEDs on 55A-PWD<br />

LED<br />

Function<br />

CD +5 V LED ON: faultless<br />

PA 24 V LED OFF: fault<br />

PB 36 V<br />

PB 36 V overvoltage LED ON: Supply voltage too high<br />

LED OFF: Supply voltage correct<br />