18.06.2014 Views

AGFA d-lab.3 Digital Compact Lab

AGFA d-lab.3 Digital Compact Lab

AGFA d-lab.3 Digital Compact Lab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Paper Processor<br />

Repair<br />

55P-SSR<br />

Fuses and LEDs:<br />

Fuse SSR no. Load LED<br />

F1 (250 V/2,5 A) U1 DEV heater HT1PCT D1<br />

F2 (250 V/2,5 A) U2 BF heater HT2PCT D2<br />

F3 (250 V/2,5 A) U3 STB 1 heater HT3PCT<br />

F4 (250 V/2,5 A) U4 STB 2 heater HT4PCT D3<br />

F5 (250 V/2,5 A) U5 STB 3 heater HT5PCT<br />

F6 (250 V/5 A) U6 Main drive motor MO1PPD<br />

F7 (250 V/2,5 A) U7 Driver motor of the sorter MO1PSO<br />

F8 (250 V/2,5 A) U8 Circulation pumps DEV, BF and STB MO1PPP<br />

:<br />

:<br />

MO5PPP<br />

F9 (250 V/1 A) U9 DEV replenishing pump MO1PRP<br />

U10 BF replenishing pump MO2PRP<br />

U11 STB replenishing pump MO3PRP<br />

F10 (250 V/2 A) U16 Mixer of replenishment chemicals (CW) MO1PRD<br />

U17 Mixer of replenishment chemicals (ACW) MO1PRD<br />

F11 (250 V/5A) U 18 not used<br />

F12 (250 V/1 A) U12 DEV water replenishing pump MO1PRW<br />

U13 BF water replenishing pump MO2PRW<br />

U14 STB water replenishing pump MO3PRW<br />

U15 Water replenishing pump of the<br />

measuring tanks<br />

U19 ASTOR pump (not used)<br />

7.3.6 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>