18.06.2014 Views

AGFA d-lab.3 Digital Compact Lab

AGFA d-lab.3 Digital Compact Lab

AGFA d-lab.3 Digital Compact Lab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Repair<br />

Paper Processor<br />

Electrical Structure<br />

PCBs / Power Supply<br />

dlabr160<br />

1 ⎯ Densitometer board 2)<br />

2 55P-MDV Driver board for<br />

- Motors<br />

- Lane Shifter<br />

- Outlet Unit<br />

- Pressure solenoid of the densitometer measuring head<br />

- 24V DC fan<br />

3 SSR2 Activation of the dryer fan (connection on CL8) 1)<br />

4 SSR3 Activation of the IR dryer 1)<br />

5 56P-SDR Control of the water replenishment<br />

6 55P-CPU Main processor of the Paper Processor<br />

7 55P-IRC Control of the IR dryer (IR heater / IR dryer fan)<br />

8 55P-SSR Board with the Solid State Relays for the activation of the<br />

- Solution heaters<br />

- Pumps<br />

- Main drive motor<br />

- AC motor 3)<br />

9 55A-PWD Voltage control<br />

10 ⎯ Power supply<br />

11 56A-FUR Fuse board<br />

1) Both Solid State Relays are behind the 55P-CPU<br />

2) Replace the densitometer board only together with the measuring head<br />

3) The SSR for the dryer heater (SSR1) is located in the AC power supply<br />

A<br />

B<br />

Paper Processor electronic<br />

AC/DC power supply<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 7.3.3