Repair<br />

Paper Processor<br />

General Overview<br />

Sensors and Loads in the Paper Processor<br />

Processor Block (PP)<br />

FA1PPP<br />

Cooling fan for DEV<br />

FA2PPP, FA3PPP Cooling fan for BF<br />

FA4PPP<br />

Cooling fan for STB<br />

FA5PPP<br />

Cooling fan for Processor block<br />

FA6PPP<br />

Cooling fan for transport motor<br />

FA7PPP<br />

Cooling fan for DEV circulation pump<br />

FS1PET - FS3PET Level switch effluent tanks<br />

FS1PRT - FS3PRT Level switch replenishment tanks<br />

FS1PRW<br />

Level switch water replenishment tanks<br />

FS2PRW<br />

Level switch evaporation measuring tanks<br />

FS1PTK - FS5PTK Level switch temperature control tanks<br />

HS1PCT - HS3PCT Temperature sensors control tanks<br />

HT1PCT<br />

Heater DEV<br />

HT2PCT<br />

Heater BF<br />

HT3PCT - HT5PCT Heater STB<br />

LS1PRD<br />

Mixer motor rotation control<br />

MO1PPD<br />

Main drive<br />

MO1PPP<br />

Circulation pump for DEV<br />

MO2PPP<br />

Circulation pump for BF<br />

MO3PPP - MO5PPP Circulation pump for STB1-3<br />

MO1PRD<br />

Replenisher Mixer<br />

MO1PRP<br />

Replenisher pump DEV<br />

MO2PRP<br />

Replenisher pump BF<br />

MO3PRP<br />

Replenisher pump STB<br />

MO1PRW<br />

Pump DEV water replenishment<br />

MO2PRW<br />

Pump BF water replenishment<br />

MO3PRW<br />

Pump STB 3 water replenishment<br />

MO4PRW<br />

Water pump evaporation compensation tank<br />

MO6PRW<br />

Pump STB 2 water replenishment<br />

MO7PRW<br />

Pump STB 1 water replenishment<br />

MS1PTK<br />

Switch of the Processor cover<br />

MS2PTK<br />

Switch of the BF replenisher tank cover<br />

MS3PTK<br />

Processor drive interrupt, when MS1PTK activated<br />

MS4PTK<br />

Switch of the DEV replenisher tank cover<br />

MS5PTK<br />

Switch of the STB replenisher tank cover<br />

Dryer (DH)<br />

LS1PDH Dryer fan control FA1PDH<br />

FA1PDH Dryer fan<br />

FA2PDH Dryer cooling fan<br />

FA3PDH Cooling fan for dryer block<br />

FA4PDH Cooling fan for FA1PIR<br />

FA5PDH Cooling fan for FA2PIR<br />

FU1PDH Temp fuse<br />

HS1PDR Temp sensor dryer<br />

HT1PDH Dryer heater 1<br />

HT2PDH Dryer heater 2<br />

MS1PDH Dryer cover switch<br />

MS2PDH Dryer interrupt when MS1PDH is actuated<br />

TH1PDH Thermostat<br />

IR dryer (IR)<br />

HT1PIR IR dryer top<br />

HT2PIR IR dryer bottom<br />

FA1PIR Dryer fan top<br />

FA2PIR Dryer fan bottom<br />

LS1PIR Dryer fan control FA1PIR<br />

LS2PIR Paper detection<br />

LS3PIR Paper detection<br />

LS4PIR Paper detection<br />

LS5PIR Paper detection<br />

LS6PIR IR dryer control<br />

LSAPIR Dryer fan control FA2PIR<br />

TH1PIR Thermostat<br />

Paper output (PO)<br />

FA1PPO Cooling fan of the densitometer<br />

LS1PPO Paper detection 1<br />

LS2PPO Paper detection 2<br />

LS3PPO Paper detection 3<br />

LS4PPO Paper detection 4<br />

MG1PPO Pressure solenoid of the densitometer<br />

MO1PPO Drive paper exit 1<br />

MO2PPO Drive paper exit 2<br />

MG2PPO Transport direction switch-over<br />

Lane Shifter (LS)<br />

LS1PLS Detection Lane Shifter in reference position<br />

LS2PLS Detection flap in reference position<br />

MO1PLS Lane Shifter drive motor<br />

MO2PLS Flap movement<br />

Sorter (SO)<br />

LS1PSO Detection Sorter in reference position<br />

MO1PSO Sorter drive<br />

MS1PSO Sorter closed detection<br />

dlabr12<br />