Printer<br />

Repair<br />

Replacing the AOM Amplifier<br />

AOM = acoustooptical Modulator<br />

Replacement required:<br />

AOM defective<br />

The d-<strong>lab.3</strong> is equipped with an AOM amplifier each<br />

for the blue and the green laser beam:<br />

− LA_BE04 (1), blue<br />

− LA_BE04 (2), green<br />

Watchmaker screwdriver<br />

Allan key<br />

Replacement:<br />

− Pull out the PE<br />

− Draw the power plug<br />

− Unscrew the top screw (3), slacken the bottoms<br />

screw; do not disconnect the data cable (4)<br />

− Remove the AOM, disconnect the data cable (4)<br />

− LA_BE04 (1)<br />

− LA_BE04 (2)<br />

− Connect the new AOM to the data cable and the<br />

power supply:<br />

Adjust the AOM before screwing it down.<br />

− Find a new characteristic curve (adjustment by<br />

means of the Service program):<br />

For this, move an additional monitor diode into<br />

the light path<br />

− Screw down the AOM<br />

− Restart the d-<strong>lab.3</strong><br />

dlabre48<br />

dlabr173<br />

6.4.52 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>