Printer<br />

Repair<br />

Replacing the Set of Belts at the bottom<br />

Replacement required:<br />

Belts or rollers damaged by a paper jam<br />

Allan keys 3 and 4<br />

Screwdriver<br />

Spanners 13 and 9<br />

Removal:<br />

− Pull out the PE<br />

− Open the set of belts<br />

− Remove the locking lever on the left side:<br />

Remove the safety spring (1)<br />

− Remove the sensor holder (2) with sensor<br />

PE_LS02<br />

− Detach the spring (3) on the actuator<br />

− Open the circlip (4) on the toggle, push in<br />

actuator piston<br />

− Remove the toggle (5)<br />

− Dismount the sensor PE_GS03 (6) with the<br />

holder<br />

− Unscrew the Allan screws (7) (key size 13) on<br />

both sides of the cast frame:<br />

The set of belts only hangs on 1 supporting screw<br />

(8) on either side<br />

− Remove the supporting screw on the right side,<br />

only slacken it on the left side until the set of belts<br />

is free<br />

− Remove the set of belts<br />

dlabr289<br />

Installation:<br />

− Put the new set of belts in the supporting screws<br />

first, tighten the screws<br />

− Mount 2 Allan screws on either side<br />

− Check the belt mounting position<br />

− Mount sensor PE_GS03<br />

− Mount the toggle:<br />

Do not unscrew the eccentric screw (lacquersealed,<br />

specific gap dimension)!<br />

− Mount the sensor holder with sensor PE_LS02<br />

− Hang in the spring<br />

− Mount the locking lever<br />

− Close the set of belts<br />

dlabr290<br />