Repair<br />

Printer<br />

Replacing the Light Sensors PE_LS05 (BOP)<br />

Replacement required:<br />

Light sensor (integrated on PE_GS03; sensor sheet<br />

tip; transmitter/receiver LS) defective<br />

Allan key 3<br />

Cross tip screwdriver<br />

Service cables L9.8060.9001.1 and L9.8060.9002.1<br />

Removal:<br />

− Pull out the PE<br />

− Remove the rear cover plate<br />

− Remove the holder with the sensor (2)<br />

− Disconnect the cable from PE_GS03<br />

− Unscrew PE_GS02 from the holder<br />

Installation:<br />

− Mount a new GS<br />

− Connect the cable<br />

− Mount the sensor with the holder<br />

− Mount the cover plate<br />

dlabr097<br />

1. Check the adjustment sensor<br />

− Connect the service cable<br />

− Call up the service program and execute:<br />

Scripts\printer\data_pe\<br />

Lichtschranken\pe_ls05-begin of<br />

paper-sensor.txt<br />

− No. of cycles 0: The sensor is constantly<br />

checked<br />

− Enter the paper at PE at the bottom, mind the<br />

display in the field Information<br />

− The sensor function is OK when the message<br />

BOP see Paper is displayed<br />

2. Check BOP on the print<br />

(Script for this in preparation)<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.4.37