Printer<br />

Repair<br />

Replacing the Motor PE_MO02<br />

Replacement required:<br />

Motor defective<br />

Allan keys 1,5 and 3<br />

Screwdriver<br />

Removal:<br />

− Pull out the PE<br />

− Disconnect the cable of MO02 (at the bottom;<br />

brown)<br />

− Disconnect the sensor cable from PE_LS04<br />

− Unscrew the Allan screw 1,5 on the motor side of<br />

the clutch<br />

− Remove the motor plate with the motor and the<br />

sensor from the vibration absorbers:<br />

Unscrew 3 Allan screws<br />

− Detach the motor from the motor plate:<br />

4 slotted countersunk head screws<br />

Installation:<br />

1 Motor PE_MO02: Drive feed and exit roller PE<br />

2 Gearing<br />

dlabr099<br />

− Change the motor<br />

− Mount the motor plate:<br />

Mind the location of the vibration absorbers and<br />

the clutch; screw in the screws tight up to the<br />

stop (sleeve and rubber buffer)<br />

− Connect the motor and sensor cables<br />

Adjustment:<br />

Test the function in the Service program<br />

6.4.34 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>