Printer<br />

Repair<br />

Replacing the Turntable<br />

Replacement required:<br />

In case of damage<br />

The turntable must be replaced together with the<br />

turntable shaft as the parts are lacquer-sealed!<br />

Allan key 3,0<br />

Seeger circlip ring pliers<br />

Removal:<br />

− Pull out the TU<br />

− Unlock the bottom unit and fold it down<br />

− Unscrew the cover of the printed circuit and<br />

disconnect all cables to drive unit 1:<br />

ST 6, 9, 10, 17, 21, 22, 23, 25<br />

− Tilt away the complete printed circuit with the<br />

carrier plate; unscrew 2 screws<br />

− Unscrew drive unit 1 and remove it towards<br />

the bottom: 5 screws (1) at the front, 3 screws<br />

at the back<br />

− Open the Seeger circlip ring and strip off the sync<br />

disk with the toothed belt<br />

Installation:<br />

Make sure that the assembly group is put exactly in<br />

the recesses when mounted, otherwise no correct<br />

paper transport can be guaranteed.<br />

1 Fastening screw (1st of 5 front)<br />

dlabr213<br />

Check the toothed belt tension<br />