Repair<br />

Printer<br />

Replacing the Sync Disks 7.8060.TUBH. / outer Toothed Belt 7.0389.6121.<br />

Dynamometer<br />

Seeger circlip ring pliers 3 – 10 mm ∅<br />

− Remove the Seeger circlip ring<br />

− Replace the sync disks (1) and (3):<br />

The collar of the sync disks must be alternately<br />

on the belts. Risk of confusion!<br />

− Adjust the belt tension (2) by shifting the<br />

tensioning plate:<br />

The screw heads (4) to fasten the tensioning<br />

plate must not be on the belt side!<br />

dlabr207<br />

Measure the belt tension in position (2):<br />

1 Sync disk, flange out<br />

2 Test point of the belt tension<br />

3 Sync disk, flange in<br />

4 Screw head not on the belt side<br />

− Deflection of the toothed belt: 1,7 mm<br />

− Test load: 1,0 N<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.4.25