Printer<br />

Repair<br />

Replacing the Pressure Roller .SGAG / Torsion Spring .SGKC<br />

Replacement required:<br />

− Pressure roller damaged<br />

− If the cut is not accurate, the torsion springs must<br />

be replaced to ensure the prescribed pressure<br />

force.<br />

Flat pliers<br />

Screwdriver<br />

Dynamometer 100 N<br />

− Hang out the springs on the counter pressure<br />

roller .SGAQ<br />

− Use the pliers to detach the spring from the<br />

plate on the side of the motor SG_MO01<br />

− On the other side, the spring can be detached<br />

from the shaft<br />

− Open the circlips and take out the shaft with the<br />

pressure roller<br />

− Remove the circlip and the washer in front of the<br />

pressure roller<br />

− Pull the pressure roller with the bearings off the<br />

shaft<br />

Pressure force of the pressure roller: 74+/-4N<br />

6.4.22 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>