Printer<br />

Repair<br />

Replacing the Motor SG_MO02<br />

Replacement required:<br />

If the motor is defective, the rocker does not move<br />

any more.<br />

Allan key 2,5<br />

Removal:<br />

− Open the circlip (on coupling .SGAS)<br />

− Unscrew the motor through the holes in the<br />

holding plate<br />

− Remove the motor with the code disk and the<br />

crank<br />

− Dismount the motor, the code disk and the crank<br />

Installation:<br />

− Installation in reverse order<br />

− The parts cannot be mixed up when they are<br />

mounted.<br />

The slide bearings between the crank and the<br />

coupling must point to the inside to the motor!<br />

Replacing the toothed Belt<br />

Replacement required:<br />

Toothed belt torn or damaged<br />

Allan key 3,0 angled<br />

Ball head screwdriver 3,0<br />

Dynamometer<br />

− Unscrew the motor SG_MO01 so that the belt<br />

tension slackens<br />

− Change the belt and screw down the motor<br />

Measure the belt tension with the dynamometer:<br />

1,0 N<br />

6.4.20 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>