Repair<br />

Printer<br />

Replacing the Motor SG_MO01<br />

Replacement required:<br />

If the motor is defective, the paper does not pass<br />

any more through the SG.<br />

The motor can only be replaced together with the<br />

sync disk.<br />

Allan key 2,0<br />

Allan key 3,0 angled<br />

Ball head screwdriver 3,0<br />

Dynamometer<br />

Removal:<br />

− Unscrew the .SGAJ cover:<br />

3 Allan screws 2,0<br />

− Cut the cable ties and unscrew the motor<br />

Installation:<br />

− Adjust the correct belt tension by shifting the<br />

motor<br />

− Screw on the motor very tight, using the angled<br />

screwdriver!<br />

Caution!<br />

When mounting the .SGAJ cover, make sure that a<br />

lock washer and a washer are used on each screw.<br />

If this is not done, the screw may damage the cable.<br />

Measure the belt tension with the dynamometer:<br />

1,0 N<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.4.19