Printer<br />

Repair<br />

Replacing the Switching Gear SG<br />

Replacement required:<br />

The ML/MR → Sheet Bridge (SB) transfer does not<br />

work<br />

The assembly group has to be removed from the<br />

Printer for all jobs on the SG.<br />

Allan key<br />

Removal:<br />

− Remove Switching Gear (1):<br />

Pull the left bracket vigorously as the assembly<br />

group is very tight in the guide.<br />

Installation:<br />

− When mounting the assembly group, make sure<br />

that the guides lock under the pins with the<br />

springs.<br />

− The connector for the SG is located on the fan<br />

assembly group<br />

1<br />

d<br />

labr146<br />

Replacing the Printed Circuit SG_GS02<br />

Replacement required:<br />

If the SG_GS02 is defective, the paper cannot be<br />

turned round any more.<br />

Allan key 2,5<br />

Back of SG_GS02:<br />

Unscrew 3 Allan screws 2,5<br />

Caution!<br />

Mind the code disk .SGBE of the motor upon the<br />

removal / installation!<br />

6.4.18 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>