Repair<br />

Printer<br />

Transmit software and setup values to the<br />

Printer Mainboard (in this sequence)<br />

− Switch on voltages:<br />

Switch on d-lab, or execute the script Script<br />

for service/initialisation/<br />

start_up_d-lab.txt<br />

Check the software on the Printer Mainboard<br />

The following software elements are stored on the<br />

Printer Mainboard, and in case of PCB replacement<br />

they must be updated:<br />

− Firmware Printer Mainboard (prhp.hex)<br />

− Firmware XILINXS (prxi.hex)<br />

− And further:<br />

Firmware Printer – Bootloader (bl.hex).<br />

This file is not replaced during the update.<br />

− SETUP parameters of the Printer assemblies<br />

On spare PCBs from stock there is usually an<br />

unknown firmware version (also see Important<br />

note, next page).<br />

The setup values do not correspond either to the<br />

repaired machine. (Usually default values)<br />

Therefore a software check for the new Printer<br />

Mainboard must be made:<br />

− Check via Service / Firmware Version.<br />

− Compare the displayed result with the required<br />

version of the software package present in the<br />

machine:<br />

The firmware belonging to a certain software<br />

package can be determined subsequently.<br />

− Activate the Windows Explorer (via Watchdog)<br />

− Open the file label.txt. Path:<br />

C:\SoftwareVersion/PR/Install/<br />

PR_Vxxx-y/label.txt<br />

Information from <strong>Lab</strong>el.txt:<br />

Here HP stands for prhp.hex and XI for prxi.hex<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.4.5