Repair<br />

Printer<br />

PO_GS01 (L8.8060.2200.) - Power Monitor<br />

Functional Description<br />

PO_GS01: L8.8060.2200.<br />

− Control and monitoring of the current supply of<br />

the Printer section<br />

− Control and monitoring of the Laser via the SPI<br />

command interface.<br />

All output voltages are A/D converted and can be<br />

checked. For this, the commands are checked at<br />

the SPI interface in the Microcontroller and the<br />

corresponding actions are initiated.<br />

The SPI interface implemented in the Controller is<br />

activated via differential drivers (RS422).<br />

dlabr034<br />

Remote Power Supply<br />

After the Reset of the Controller, the power<br />

voltages (24V, 36V, 22,5V) are switched off. They<br />

can be switched by the SPI command.<br />

All available output voltages of the power supply<br />

unit are checked at the Remote connection, are<br />

level-converted and are sent to the 11-input 10-Bit<br />

A/D converter.<br />

A simple instrumentation amplification circuit and<br />

their 2-pole measurement ensures that no<br />

inadmissible GND loops occur.<br />

The measuring values are constantly recorded in<br />

a program loop and compared to the reference<br />

values set by commands. The result of the<br />

monitoring is shown by the LEDs which light when<br />

the corresponding voltage is in the required range.<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.3.45