Repair<br />

Printer<br />

Voltages<br />

+ 5V Logic supply<br />

+ 6,5V Logic source voltage<br />

+ 24V Supply voltage<br />

+ 36V Power voltage supply<br />

Jumper<br />

J1<br />

not plugged in<br />

Only for the service:<br />

plugged in<br />

Activation of the display LEDs, operating conditions can be checked<br />

LED Display<br />

D12 LED green Lights when logic voltage +5V is present<br />

D22 LED red Lights when Reset of the GS is active;<br />

Reset can be triggered manually with S2<br />

D13 LED yellow Only for development work; is active when the AVR Controller is<br />

triggered via an external programming unit<br />

Test Points<br />

MP1 + 5V<br />

MP2 GND GND against +5V<br />

MP3 not used<br />

MP4 not used<br />

MP5 not used<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.3.29