Repair Printer Switch-on and Reset Behaviour of the Printer Switch-on Behaviour of the Machine − Main switch (1) on the Paper Processor ON − Mains voltage present on the Main-PC − Main-PC in Sleep mode (Timer plug-in unit in operation) − Printer and Scanner unit dead dlabr125 The Timer switches on the Main-PC in accordance with the preset switch-on time 1 Main switch 2 RCD device The operating and user systems are booted The mains voltage for the Paper Processor and the power supply unit of the Printer / Scanner (via interface RS232) is switched on All secondary voltages (except the 24V/36V motor, laser, lamp voltage) are switched on The booting on the Printer Mainboard is started; all registers are initialised The FPGA is loaded (freely programmable logic circuit) Command interface to the Main-PC available Initialisation of the SPI interface (prerequisite: Reset by the Printer-µC on P4.4 inactive) The power voltages are switched on by a command of the Main-PC via the Printer Mainboard Check of the status of the motor voltages by the AVR Controller on the SPI interfaces AGFA d-lab.3 2001-01-02 /PN 9009 6.3.3

Printer Repair Behaviour upon Printer Shut-down − The Main-PC triggers a command to switch off the power voltages − The AVR Controllers supply a voltage failure message − The Main-PC switches off the supply voltage of the power supply unit Reset of the Main PC A Reset sent by the Main PC to the Printer µC can be generated via a separate line. This Reset also resets the AVR Controllers, i.e. all motors are stopped. The AVR Controller in the power monitor is not reset automatically and can thus remain in the old switching status. 6.3.4 2001-01-02 /PN 9009 AGFA d-lab.3

Repair<br />

Printer<br />

Switch-on and Reset Behaviour of the Printer<br />

Switch-on Behaviour of the Machine<br />

− Main switch (1) on the Paper Processor ON<br />

− Mains voltage present on the Main-PC<br />

− Main-PC in Sleep mode (Timer plug-in unit in<br />

operation)<br />

− Printer and Scanner unit dead<br />

dlabr125<br />

The Timer switches on the Main-PC in<br />

accordance with the preset switch-on time<br />

1 Main switch<br />

2 RCD device<br />

The operating and user systems are booted<br />

The mains voltage for the Paper Processor and<br />

the power supply unit of the Printer / Scanner (via<br />

interface RS232) is switched on<br />

All secondary voltages (except the 24V/36V<br />

motor, laser, lamp voltage) are switched on<br />

The booting on the Printer Mainboard is started;<br />

all registers are initialised<br />

The FPGA is loaded (freely programmable logic<br />

circuit)<br />

Command interface to the Main-PC available<br />

Initialisation of the SPI interface (prerequisite:<br />

Reset by the Printer-µC on P4.4 inactive)<br />

The power voltages are switched on by a<br />

command of the Main-PC via the Printer<br />

Mainboard<br />

Check of the status of the motor voltages by the<br />

AVR Controller on the SPI interfaces<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.3.3