Printer<br />

Repair<br />

ST 26: CAN – Interface<br />

PIN Signal name Comment I/O<br />

1 GND Reference potential GND O<br />

2 CANH CAN – HIGH I/O<br />

3 CANL CAN – LOW I/O<br />

4 GND Reference potential GND O<br />

The connectors ST 21, ST 22,ST 24 and ST 28<br />

have no significance.<br />

Their use does not make sense at present.<br />

ST 31: ISP– Programming connector<br />

PIN Signal name Comment I/O<br />

1 ISPCLK Programming clock O<br />

2 MODE Mode line O<br />

3 ISPDI Prog. data O<br />

4 ISPSDO Read data O<br />

5 ISPEN Enable O<br />

6 ISPRES Reset O<br />

7 + 5 Operating voltage +5 V I<br />

8 GND Reference potential GND I<br />

Jumper Assignment and LED<br />

D 1 = LED_ROT ><br />

Lights when an SPI module has logged in an<br />

Interrupt<br />

J 1 = nc<br />

J 2 = nc<br />

J 4 = nc<br />

J 5 = nc<br />

J 6 = plugged in<br />

ISPEN is passive<br />

Vacant<br />

Not plugged in, CPU works in<br />

normal mode<br />

All displays are passive<br />

CAN termination resistance<br />

active<br />

Test Points<br />

MP 3<br />

MP 4<br />

MP 23<br />

= +5 V<br />

= GND<br />

= Not used (no significance)<br />

6.2.16 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>