Printer<br />

Repair<br />

Voltages on the d-<strong>lab.3</strong><br />

24 V switchable measurable Voltage for Printer and Scanner<br />

(switched together !)<br />

36 V switchable measurable Voltage for Printer and Scanner<br />

(switched together!)<br />

28 V not switchable measurable AOM – voltage<br />

22,8<br />

V<br />

switchable and<br />

interruptible on<br />

primary side by<br />

Interlock switch<br />

measurable<br />

Scanner lamp voltage<br />

5 V not switchable measurable Scanner – Microcontroller voltage<br />

± 15<br />

V<br />

not switchable measurable Scanner and red Laser diode<br />

(switched together!)<br />

6,5 V not switchable measurable 5 V Printer – Microcontroller voltage<br />

± 9 V not switchable measurable Analogue voltage<br />

Laser Remote<br />

input<br />

(switchable)<br />

Laser Remote<br />

input<br />

(switchable)<br />

can be<br />

checked via<br />

SPI Power<br />

module<br />

can be<br />

checked via<br />

SPI Power<br />

module<br />

Unloading circuit on the Laser:<br />

− after switch-on approx. 20 min until a stable status is<br />

reached<br />

− after switch-off approx. 5 min for the fan afterrun<br />

Circuit of the Standby mode:<br />

− after activation and switch-back approx. 3 min until a<br />

stable status is reached<br />

Available test points result from the descriptions<br />

of the individual printed circuits.<br />

see Register 6.3<br />

6.1.6 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>