Repair Printer Voltage Distribution in the Printer dlabe148 AGFA d-lab.3 2001-01-02 /PN 9009 6.1.5

Printer Repair Voltages on the d-lab.3 24 V switchable measurable Voltage for Printer and Scanner (switched together !) 36 V switchable measurable Voltage for Printer and Scanner (switched together!) 28 V not switchable measurable AOM – voltage 22,8 V switchable and interruptible on primary side by Interlock switch measurable Scanner lamp voltage 5 V not switchable measurable Scanner – Microcontroller voltage ± 15 V not switchable measurable Scanner and red Laser diode (switched together!) 6,5 V not switchable measurable 5 V Printer – Microcontroller voltage ± 9 V not switchable measurable Analogue voltage Laser Remote input (switchable) Laser Remote input (switchable) can be checked via SPI Power module can be checked via SPI Power module Unloading circuit on the Laser: − after switch-on approx. 20 min until a stable status is reached − after switch-off approx. 5 min for the fan afterrun Circuit of the Standby mode: − after activation and switch-back approx. 3 min until a stable status is reached Available test points result from the descriptions of the individual printed circuits. see Register 6.3 6.1.6 2001-01-02 /PN 9009 AGFA d-lab.3

Repair<br />

Printer<br />

Voltage Distribution in the Printer<br />

dlabe148<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 6.1.5