Scanner<br />

Repair<br />

Mounting the rocker:<br />

− Remove the guide plates<br />

− Remove the bottom rubber roller:<br />

− Jam the shaft: Push a pin or a hexagon key<br />

through the hole in the motor shaft<br />

− Unscrew the marked screw<br />

− Pull off the roller<br />

− Push the rocker with the inserted spring a few<br />

mm on the shaft; for the spring position see<br />

Figure below<br />

− Turn the rocker until it sits on the motor shaft<br />

(eccentric hangs down)<br />

− Turn the spring until the long leg is on the<br />

rocker: The leg moves away from the rubber<br />

roller towards the motor shaft.<br />

− Push the rocker incl. spring completely on the<br />

shaft: The short leg of the spring slides into the<br />

recess on the shaft.<br />

− Turn the rocker against the spring tension until<br />

it rests on the negative carrier (eccentric is also<br />

in contact)<br />

− Fasten the bottom rubber roller again on the<br />

motor shaft<br />

− Put the lock washer in the rocker<br />

− Screw the blades on the negative carrier<br />

1 Blades<br />

2 Motor shaft<br />

3 Bottom rubber roller<br />

4 Rocker<br />

dlabr252<br />

4.4.18 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>