Scanner Repair Working on the Rockers The removal and installation of the two rocker motors and eccentric blocks are identical − Unscrew the cover plate incl. the light sensor − Pull out the motor − Remove the lock washer on the eccentric block Caution! Do not dismantle the eccentric block, only replace it as a complete unit. − Pull out the eccentric block: The preceding gear need not be removed; only rocker shaft A has to be pulled out a little. − Dismounting the rocker: − Remove the lock washer from the rocker eccentric − Pull out rocker shaft B: Mind the washers; note down the position − Remove the lock washer in the rocker Caution! Do not try to detach the rocker eccentric from the rocker. − Pull off the rocker with the eccentric See Figure on the next page 4.4.16 2001-01-02 /PN 9009 AGFA d-lab.3
Repair Scanner 1a Cover plate A 1b Cover plate B 2a Motor A 2b Motor B 3a Eccentric block A 3b Eccentric block B 4a Rocker shaft A 4b Rocker shaft B 5a Rocker 5b Rocker eccentric dlabr251 AGFA d-lab.3 2001-01-02 /PN 9009 4.4.17
- Page 125 and 126: Repair Scanner Scanner Optic dlab14
- Page 127 and 128: Repair Scanner Main Scan Cycle Filt
- Page 129 and 130: Repair Scanner Filter Wheel LH_MO01
- Page 131 and 132: Repair Scanner The motor is energis
- Page 133 and 134: Repair Scanner Auxiliary Shutter (D
- Page 135 and 136: Repair Scanner Position Auxiliary D
- Page 137 and 138: Repair Scanner Amplifiers, function
- Page 139 and 140: Repair Scanner Lenses − Fixed foc
- Page 141 and 142: Repair Scanner Functions and Proper
- Page 143 and 144: Repair Scanner Film Drive NC_MO01 T
- Page 145 and 146: Repair Scanner Control The Motherbo
- Page 147 and 148: Repair Scanner FD/SD Output Stage (
- Page 149 and 150: Repair Scanner Functions: − Contr
- Page 151 and 152: Repair Scanner The TFS is not perfo
- Page 153 and 154: Repair Scanner CG Controller (CCD G
- Page 155 and 156: Repair Scanner Driver Sensor Board
- Page 157 and 158: Repair Scanner I 2 C Bus The 2-Bit
- Page 161 and 162: Repair Scanner Repair / Adjustments
- Page 163 and 164: Repair Scanner Shutter Toothed belt
- Page 165 and 166: Repair Scanner − Check the belt d
- Page 167 and 168: Repair Scanner 2-Film Feeder Dismou
- Page 169 and 170: Repair Scanner Installing the Feede
- Page 171 and 172: Repair Scanner Feeder rocker Feeler
- Page 173 and 174: Repair Scanner − Light sensor act
- Page 175: Repair Scanner Changing the Lifting
- Page 179 and 180: Repair Scanner Changing the Light S
- Page 181 and 182: Repair Scanner Replacing the Zoom /
- Page 183 and 184: Repair Scanner Precanner Adjustment
- Page 185 and 186: Repair Scanner Remove the following
- Page 187 and 188: Repair Scanner Scanner Calibration
- Page 189 and 190: Repair Scanner White Balance A whit
- Page 191 and 192: Repair Scanner Moment of Execution
- Page 193 and 194: Repair Main-PC Contents Overview ..
- Page 197 and 198: Repair Main-PC Overview Main-PC dla
- Page 199 and 200: Repair Main-PC Drives Drives (drive
- Page 201 and 202: Repair Main-PC PC Mainboard Connect
- Page 203 and 204: Repair Main-PC BIOS Settings AWARD
- Page 205 and 206: Repair Main-PC Operating System Win
- Page 207 and 208: Repair Main-PC Repair Removal of th
- Page 209 and 210: Repair Printer Contents General Ove
- Page 211 and 212: Repair Printer Removal, Installatio
- Page 215 and 216: Repair General Overview Sensors and
- Page 217 and 218: Printer Repair Electrical Structure
- Page 219 and 220: Printer Repair Voltages on the d-la
- Page 221: Printer Repair ■ 6.1.8 2001-01-02
- Page 225 and 226: Printer Repair Printer Mainboard PF
Scanner<br />
Repair<br />
Working on the Rockers<br />
The removal and installation of the two rocker<br />
motors and eccentric blocks are identical<br />
− Unscrew the cover plate incl. the light sensor<br />
− Pull out the motor<br />
− Remove the lock washer on the eccentric block<br />
Caution!<br />
Do not dismantle the eccentric block, only replace<br />
it as a complete unit.<br />
− Pull out the eccentric block:<br />
The preceding gear need not be removed; only<br />
rocker shaft A has to be pulled out a little.<br />
− Dismounting the rocker:<br />
− Remove the lock washer from the rocker eccentric<br />
− Pull out rocker shaft B:<br />
Mind the washers; note down the position<br />
− Remove the lock washer in the rocker<br />
Caution!<br />
Do not try to detach the rocker eccentric from the<br />
rocker.<br />
− Pull off the rocker with the eccentric<br />
See Figure on the next page<br />
4.4.16 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>