Repair<br />

Scanner<br />

− Light sensor actuator:<br />

15 ± 0,1 mm after the adjustment with the<br />

metal gauge (15 mm wide)<br />

Adjust the Feeder and move it into zero position<br />

(distance 15 mm, move the driver in closed direction<br />

of the skids)<br />

− Detach the light sensor actuator and move it<br />

into the light sensor from the outside until<br />

the latter responds<br />

− Fasten the light sensor actuator<br />

− After opening the skids to size 120 and<br />

closing them again to zero position, the dimension<br />

between the skids must be again<br />

15 ± 0,1 mm.<br />

− If necessary, correct the light sensor actuator<br />

1 Light sensor actuator<br />

2 Gauge<br />