Scanner<br />

Repair<br />

Additional drive:<br />

− Pressure force of the counter roller in closed<br />

condition, measured under spring load when<br />

the air gap between the rollers disappears<br />

(before the rollers are lifted)<br />

7 - 9 N (meter)<br />

− Film tractive force; drive active, force to stop<br />

the film while the drive is running<br />

F ≥ 2,0 N (test leader, spring balance)<br />

Light sensors FF_LS02 and FF_ LS04:<br />

− Height of the light sensors<br />

Distance between varnished surface on<br />

Feeder cast part and front surface of reflected<br />

light sensor<br />

FF_LS02 and FF_LS04<br />

x = 8,5 ± 0,5 mm (calliper gauge)<br />

dlabr231<br />

Adjustment of the Feeder:<br />

− x direction:<br />

Distance between the upper FF rocker and the<br />

negative carrier 135FF<br />

∆x = 0,5 ± 0,1 mm (feeler gauge)<br />

− Operate the rocker manually:<br />

Dimension at the narrowest point ∆x<br />

dlabr232<br />

1 Negative mask<br />

2 Feeder rocker<br />

4.4.12 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>