Scanner<br />

Repair<br />

Replacing the Filter Motor / the Light Sensor<br />

Toothed belt pulley motor:<br />

Clamping tool<br />

Starting torque 1,8 Nm ± 0,1 Nm<br />

Light sensor:<br />

Axial distance to filter wheel (visual check)<br />

> 0,5 mm<br />

Toothed Belt Pulleys, Adjustment<br />

Toothed belt pulleys:<br />

Aligned<br />

Height mismatch ≤ 1 mm<br />

The belt must not brush<br />

Dust Shutter<br />

Omitted in mass production<br />

Light sensor:<br />

− The paddle must not brush:<br />

A Paddle centred between the base and cover<br />

plate and parallel<br />

B Paddle brushes on the sliding foil; parallel<br />

alignment with the base plate<br />

C Paddle not at an angle on the motor shaft or<br />

sagging; unparalleled alignment with respect<br />

to the base plate; the paddle only brushes<br />

on the sliding foil at the end of the swivel<br />

area<br />

− Light sensor position<br />

Move the paddle in home position (initialisation)<br />

Offset adjustment by the Software; no light sensor<br />

adjustment required.<br />

1 Paddle<br />

2 Sliding foil<br />

3 Cover plate<br />

4 Base plate<br />

dlabr226<br />