Repair<br />

Scanner<br />

Repair / Adjustments<br />

KG Segment<br />

1 IR filter (golden shining side up)<br />

2 Belt<br />

3 Light dimmer<br />

4 KG5 glass<br />

5 UV/IR filter, swivelling<br />

Toothed belt adjustment:<br />

Belt tension 110 Hz ± 10%<br />

Meter<br />

F = 1,2 ± 0,1 N<br />

with 2 mm deflection<br />

(see Fig. on the next page)<br />

The steel core ends of the belt are opposite the<br />

test point<br />

Belt tension meter or meter<br />

Calliper gauge<br />

− Check the belt tension with a belt tension meter<br />

dlabr219<br />

dlabr220<br />

1 Toothed belt<br />

2 Steel core cut<br />

3 Measuring head (frequency measurement on the<br />

other side of the steel core ends)<br />