Scanner<br />

Repair<br />

Bus Systems and Interfaces<br />

CAN Bus<br />

The CAN Bus is used for the internal<br />

communication of the Scanner Hardware.<br />

The following units are connected to the CAN Bus:<br />

− FL Controller as Master<br />

− Algorithm/interface board<br />

− CG Controller<br />

− APS Cartridge Feeder<br />

− Zoom (Lens Group)<br />

The ID of the CAN nodes is set in the Software and<br />

not by way of DIP switches.<br />

The Software protocol is specified in Register 8<br />

Software.<br />

LVDS<br />

Interface (differential line pairs) between the CG<br />

Controller and the image processing board in the<br />

Main PC.<br />

RS232<br />

Serial interface between the Motherboard and the<br />

Main PC.<br />

Ethernet<br />

There are 2 network boards with a transmission<br />

speed of 10 MBit/sec and 100 MBit/sec in the<br />

Main PC.<br />

The 10 MBit board is used for the data transfer<br />

between the algorithm/interface board and the<br />

image processing board (VIPS) in the Main PC.<br />

The 100 MBit board connects the d-<strong>lab.3</strong> to an<br />

external network.<br />

4.3.34 2001-01-02 /PN 9009 <strong>AGFA</strong> d-<strong>lab.3</strong>