Repair<br />

Scanner<br />

Amplifiers, functions:<br />

− Setting the optimum amplification for the check of<br />

the photodiodes. For optimum utilisation of the<br />

modulation of the AD converter, the amplification<br />

factor for the current / voltage conversion can be<br />

modified.<br />

− Converting the current of the photodiodes into a<br />

voltage.<br />

Only the current of a photodiode is proportional<br />

to the infalling light. For this reason, the light<br />

must be measured here. The AD converter<br />

switched behind can only measure voltages.<br />

The amplification of the current/voltage converter is<br />

adjustable by the film drive processor.<br />

Functions:<br />

− The Prescanner is used to analyse the frames<br />

prior to the actual exposure and main scan<br />

procedure in the d-<strong>lab.3</strong>:<br />

For the Prescan, the Prescanner is moved into<br />

the light path and the film is passed over the<br />

Prescanner. For single frames, the Prescanner is<br />

put under the stationary frame. The film is<br />

digitised at low resolution while the colour and<br />

density values of the entire film including the<br />

border are collected.<br />

− The digitised data is transmitted to the FL<br />

Controller where the required integration times<br />

are found for each colour depending on:<br />

− the density of the individual frame<br />

− the colour corrections as a function of the film<br />

mask<br />

− the colour corrections as a function of a<br />

general colour cast on the film, e.g. on<br />

artificial light shots<br />

− Reading the DX code<br />

− Detecting the image boundaries for the<br />

subsequent image positioning<br />

− Exact image positioning during the film transport<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 4.3.15