Repair<br />

Scanner<br />

Filter Wheel LH_MO01<br />

The filter wheel stepper motor is connected to the<br />

filter wheel by a toothed belt. The filter wheel can<br />

hold eight filters (in cw order):<br />

1. free<br />

2. RED-Negative<br />

3. RED-Slide<br />

4. GREEN-Negative<br />

5. GREEN-Slide<br />

6. BLUE-Negative<br />

7. BLUE-Slide<br />

8. Light dimmer<br />

The zero position is reached with light sensor<br />

LH_LS01.<br />

The motor is energised by different currents via<br />

LH_MO01_I0 and LH_MO01_I1:<br />

A<br />

B<br />

Arrow<br />

dlabr153<br />

Zero position (position for the 1 st exposure)<br />

Initialisation position (Position LH_LS01)<br />

Direction of rotation<br />

I0 0 1 0 1<br />

I1 0 0 1 1<br />

Current 100% 72% 38% 0%<br />

The motor runs in half step mode:<br />

− Step angle 1,8°<br />

− Transmission of 3:1.<br />

The filter wheel is turned through 0.3° per step.<br />

150 steps must be performed between the filters.<br />

− Direction of rotation of the filter with a cw turning<br />

motor: RED-Negative, RED-Slide, GREEN-<br />

Negative, etc.<br />

− Zero position of the light sensor with a cw turning<br />

motor: 6° before the RED-Negative filter<br />

− Clock: Indicated by LH_MO01_CLK<br />

− Direction: Can be selected by LH_MO01_DIR<br />

− When the lamphouse opens, the stepper motor is<br />

switched off.<br />

<strong>AGFA</strong> d-<strong>lab.3</strong> 2001-01-02 /PN 9009 4.3.7