d-lab.1
d-lab.1 d-lab.1
Modification History Version Edition Modifications 04073_00 2004-07-08 Start Version Published in compliance with EN 55022 (valid in EU): Warning! The equipment complies with the limits for a Class A device. Operation of the equipment in residential areas may cause radio interference in which case the user at his own expense will be requested to take whatever measures may be required to correct the interference. © 2004 Agfa-Gevaert AG. All rights reserved. No part of these instructions may be reproduced, copied, or transmitted in any form or by any means without prior written permission by Agfa-Gevaert AG.
Capacitor Kit d-lab.1 Content 1 List of possibly affected machines ......................................................................................................1 2 Contents of the kit..................................................................................................................................1 2.1 Additional tools...............................................................................................................................1 3 Modification ............................................................................................................................................2 3.1 Some general points before you start............................................................................................2 3.2 Information.....................................................................................................................................2 3.2.1 Problem .............................................................................................................................2 3.2.2 Countermeasure................................................................................................................2 3.3 Preparation ....................................................................................................................................2 3.3.1 Cover removal ...................................................................................................................2 3.4 How to check the capacitors..........................................................................................................5 3.4.1 Wrong and correct capacitors ...........................................................................................6 3.5 Replacement of the capacitors ......................................................................................................7 3.5.1 Removal of the LCD driver board......................................................................................7 3.5.2 Removal of the wrong capacitors ....................................................................................10 3.5.3 Installation of the new capacitors ....................................................................................11 3.5.4 Reinstallation of the LCD driver board ............................................................................12 4 Attachment ...........................................................................................................................................13 4.1 List of possibly affected machines, sorted by serial number. ......................................................13 4.2 List of possibly affected machines, sorted by country .................................................................24 AGFA d-lab.1 CM+9.8072.9003.0/DD+18070312D0/PN04073_00 i
- Page 1: Service Instructions Digital Minila
- Page 5 and 6: Modification Capacitor Kit d-lab.1
- Page 7 and 8: Modification Capacitor Kit d-lab.1
- Page 9 and 10: Modification Capacitor Kit d-lab.1
- Page 11 and 12: Modification Capacitor Kit d-lab.1
- Page 13 and 14: Modification Capacitor Kit d-lab.1
- Page 15 and 16: Modification Capacitor Kit d-lab.1
- Page 17 and 18: Attachment Capacitor Kit d-lab.1 33
- Page 19 and 20: Attachment Capacitor Kit d-lab.1 42
- Page 21 and 22: Attachment Capacitor Kit d-lab.1 50
- Page 23 and 24: Attachment Capacitor Kit d-lab.1 58
- Page 25 and 26: Attachment Capacitor Kit d-lab.1 66
- Page 27 and 28: Attachment Capacitor Kit d-lab.1 4.
- Page 29 and 30: Attachment Capacitor Kit d-lab.1 57
- Page 31 and 32: Attachment Capacitor Kit d-lab.1 52
- Page 33 and 34: Attachment Capacitor Kit d-lab.1 45
- Page 35 and 36: Attachment Capacitor Kit d-lab.1 43
- Page 37: Attachment Capacitor Kit d-lab.1 46
Modification History<br />
Version Edition Modifications<br />
04073_00 2004-07-08 Start Version<br />
Published in compliance with EN 55022 (valid in EU):<br />
Warning!<br />
The equipment complies with the limits for a Class A device. Operation of the equipment<br />
in residential areas may cause radio interference in which case the user at his own<br />
expense will be requested to take whatever measures may be required to correct the<br />
interference.<br />
© 2004 Agfa-Gevaert AG. All rights reserved.<br />
No part of these instructions may be reproduced, copied, or transmitted in any form or by<br />
any means without prior written permission by Agfa-Gevaert AG.