Connection modes for <strong>zehnder</strong> <strong>charleston</strong> <strong>completto</strong> radiators and special design radiators<br />

<strong>zehnder</strong> <strong>charleston</strong><br />

Connection codes - <strong>zehnder</strong> <strong>charleston</strong> <strong>completto</strong> (additional cost applies)<br />

1/2" L<br />

L 1/2"<br />

1/2" L<br />

1/2" L<br />

1/2" L<br />

V 1/2" R 1/2"<br />

V 1/2" R 1/2"<br />

V 1/2" R 1/2"<br />

V 1/2" R 1/2"<br />

built-in valve on top,<br />

bottom, same-side connection<br />

built-in valve on the bottom,<br />

bottom, same-side connection<br />

built-in valve on top,<br />

bottom, middle connection<br />

built-in valve on top,<br />

bottom, opposite-side connection<br />

V = flow, R = return, L = air vent, E = water drain, B = blind plug, O = buffle (standard), • = buffle (100% watertight)<br />

Special designs<br />

Description<br />

Additional special connections<br />

Fully welded construction<br />

high-pressure design max. 18 bar (not possible for Completto design)<br />

Angled or curved design<br />

Radiator design over 3000 mm high<br />

For an additional cost<br />

(calculated upon request).<br />

Welded-on lifting eyes<br />

Extended length radiator, assembled from segments using nipples<br />

Zinc-plated construction<br />

(see explanation on page 416)<br />

Zinc plating with subsequent finishing using enamel of standard colour (RAL 9016)<br />

Insert tube<br />

In the event a Zehnder Charleston radiator has same-side connections<br />

and the number of its sections exceeds the number indicated<br />

below, the radiator may be designed with a factory-installed insert tube<br />

that will guarantee achieving the heat capacity ratings shown in<br />

the catalog (additional cost applies)<br />

2-column model<br />

3-column model<br />

4-column model<br />

5-column model<br />

6-column model<br />

from 87 sections = installation length 4002 mm<br />

from 85 sections = installation length 3910 mm<br />

from 81 sections = installation length 3726 mm<br />

from 71 sections = installation length 3266 mm<br />

from 55 sections = installation length 2530 mm<br />

Einsatzrohr<br />

Insert tube<br />

1<br />

/3 2<br />

/3<br />

Supply Vorlauf<br />

Rücklauf<br />

Return<br />

9