Technical parameters<br />

<strong>zehnder</strong> <strong>charleston</strong> - <strong>zehnder</strong> <strong>charleston</strong> <strong>completto</strong><br />

Valve in upper part of the radiator,<br />

bottom, same-side connection<br />

2-column<br />

model<br />

3-column<br />

model<br />

4-column<br />

model<br />

5-column<br />

model<br />

6-column<br />

model<br />

A<br />

62<br />

100<br />

136<br />

173<br />

210<br />

L<br />

BH<br />

14<br />

21<br />

50<br />

46<br />

14<br />

6<br />

31<br />

50<br />

68<br />

86,5<br />

105<br />

BL<br />

Valve in upper part of the radiator,<br />

bottom center connection<br />

Valve in upper part of the radiator,<br />

bottom, opposite-end connection<br />

A<br />

46<br />

1/2"L<br />

1/2"L<br />

1/2"L<br />

A<br />

1/2"B<br />

O<br />

14<br />

21<br />

V R<br />

50<br />

BL<br />

46<br />

14<br />

21<br />

V<br />

BL<br />

R<br />

21<br />

Valve in lower part of the radiator,<br />

bottom, same-side connection<br />

1/2"L<br />

A<br />

14<br />

21<br />

V R<br />

50<br />

BL<br />

46<br />

1/2"L<br />

1/2"B<br />

14<br />

Total length, including valve and plug = BL + 119 mm<br />

BH = effective height, table value<br />

= (see starting page 64)<br />

= nominal height minus 8 mm<br />

= (for 2-column models) (exception: 190 and 260 mm)<br />

= nominal height<br />

= (for 3 to 6-column models) (exception: 190 mm)<br />

BL = length<br />

= number of sections x 46 mm<br />

A = thermostat protrusion 105 mm<br />

V = flow<br />

R = return<br />

L = air vent<br />

B = plug<br />

Distance to the wall and distance from the wall to connection<br />

centerline depend upon mounting mode and braket type.<br />

Attention: in this design, the heat capacity of the first section<br />

will be lower due to insufficient water circulation.<br />

Technical parameters of the valve<br />

Built-in regulator valve OV 1” (for 2-column models) or OV 5 /4”<br />

(for 3 to 6-column models), installed at the factory.<br />

Maximum recommended water flow rate: 250 kg/hr<br />

Information on regulator valve – additional.<br />