After a time delay (normally 0.3s), the delayed contact of the brake contactor opens, which disconnects the<br />

supply from terminal 3 and the rectifier changes to a half wave type. Half wave operation prevents heating of<br />

the brake coil and is enough to keep the brake open.<br />

To close the brake, the brake contactor disconnects the supply to terminals 1 and 2. The released brake<br />

contactor also opens the brake coil DC-circuit, which speeds closing of the brake. The purpose of the varistor<br />

there is overvoltage protection for K7 contacts and the brake coil.<br />

26/79<br />

This document and the information contained herein, is the exclusive property of R&M <strong>Materials</strong> <strong>Handling</strong> Inc. and represents a non-public, confidential and proprietary<br />

trade secret that may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M<br />

<strong>Materials</strong> <strong>Handling</strong> Inc. Copyright © (2005) R&M <strong>Materials</strong> <strong>Handling</strong> Inc. All rights reserved.