R&M <strong>Materials</strong> <strong>Handling</strong>, Inc.<br />

4501 Gateway Boulevard<br />

Springfield, Ohio 45502<br />

P.: (937) 328-5100<br />

FAX: (937) 325-5319<br />

3.4 Brake controllers<br />

3.4.1 REC12<br />

Brake control unit REC12 is a line voltage half-wave rectifier for DC-brakes.<br />

Voltage range<br />

200...690Vac<br />

AC Line Voltage<br />

Output voltage U DC<br />

Half wave 0.45 x U AC<br />

Maximum current<br />

1.25Adc<br />

K7<br />

K7<br />

L1-1 L1-2<br />

L2<br />

a<br />

K7<br />

K7<br />

b<br />

REC12<br />

Brake<br />

When the brake is opened, the brake contactor K7 connects two phases of mains voltage to terminals L1 and<br />

L2. In addition, the brake contactor shorts terminals a and b thus making the DC-circuit.<br />

To close the brake, the brake contactor disconnects the supply to terminals L1 and L2. The released brake<br />

contactor also opens the brake coil DC-circuit, which speeds closing of the brake. The purpose of the varistor<br />

there is overvoltage protection for K7 contacts and the brake coil.<br />

3.4.2 ESD141<br />

Brake control unit ESD141 is a line voltage full/half-wave rectifier for DC-brakes.<br />

Voltage range<br />

200...690Vac<br />

AC Line Voltage<br />

Output voltage U DC<br />

Full wave 0.90 x U AC<br />

Half wave 0.45 x U AC<br />

K7<br />

K7<br />

Maximum current<br />

1.25Adc continuous and 2.5Adc at ED5%<br />

K7<br />

Set 0.3s<br />

3<br />

2<br />

1<br />

4<br />

K7<br />

K7<br />

5<br />

ESD141<br />

6 7<br />

Brake<br />

When the brake is opened, the brake contactor K7 connects two phases of mains voltage to terminals 1, 2 and<br />

3, which makes the device a full wave rectifier. The full wave mode is used to get the brake open fast. In<br />

addition, the brake contactor shorts terminals 4 and 5 thus making the DC-circuit.<br />

25/79<br />

This document and the information contained herein, is the exclusive property of R&M <strong>Materials</strong> <strong>Handling</strong> Inc. and represents a non-public, confidential and proprietary<br />

trade secret that may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M<br />

<strong>Materials</strong> <strong>Handling</strong> Inc. Copyright © (2005) R&M <strong>Materials</strong> <strong>Handling</strong> Inc. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!