Download - R&M Materials Handling equipment
Download - R&M Materials Handling equipment
Download - R&M Materials Handling equipment
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
R&M <strong>Materials</strong> <strong>Handling</strong>, Inc.<br />
4501 Gateway Boulevard<br />
Springfield, Ohio 45502<br />
P.: (937) 328-5100<br />
FAX: (937) 325-5319<br />
+24V<br />
RED<br />
BROWN<br />
6<br />
+24V<br />
3<br />
X1<br />
:55<br />
+24V<br />
A<br />
WHITE<br />
0V<br />
BLACK<br />
WHITE<br />
GREEN<br />
1<br />
2<br />
OUT<br />
0V<br />
4<br />
7<br />
:51<br />
EA+<br />
:56<br />
0V<br />
INVERTER<br />
:52<br />
EA-<br />
! Critical damage if: The supply voltage is over 28V or a short circuit between the signal and the<br />
supply, or induction heating or hammer mounting. In case of sensor damage, the whole motor<br />
has to be changed.<br />
Buffer amplifier must be located as close to the sensor bearing as possible (maximum distance 2.5m)<br />
The cable between the buffer amplifier and inverter must be<br />
- as far as possible from the cables of motor and braking resistor (minimum distance >20cm)<br />
- a shielded and twisted cable<br />
- grounded (the shield) at both ends, 360° grounding on inverter terminal<br />
- the shield should be grounded always when going through terminals<br />