2 INSTALLATION<br />

2.1 Cubicles<br />

Inverter is delivered with external braking resistor. Braking resistor types D2FR are installed in the same<br />

cubicle as the inverter itself. Braking resistor D2HR04F90R0S4 for 002 –005 is in own cubicle.<br />

Power class Standard cubicle Cubicle size (mm) Braking resistor (mm)<br />

002 - 005 EEO25.604 400 x 600 400 x 400<br />

007 – 015 CC600E 600 x 1000 Included<br />

018 – 030 KA220D2 1000 x 1000 Included<br />

037, 045 1½ x KA220D2 1½ x 1000 x 1000 Included<br />

055 1½ x H15BD02 1½ x 1500 x 1000 Included<br />

2.2 Braking resistor<br />

Inverter is delivered with external braking resistor. Braking resistor types D2FR are equipped with cooling<br />

fans and thermistors. Circuit diagrams are in appendix.<br />

Power class Resistance (ohm) Type<br />

002 - 005 90 D2HR04F90R0S4<br />

007 64 D2FR06F64R0S2<br />

011, 015 45 D2FR12F45R2S2<br />

018, 022 21 D2FR18F21R3S2<br />

030 16 D2FR24F16R4S2<br />

037, 045 11 2 x D2RF18F21R3S2<br />

055 8 2 x D2FR24F16R4S2<br />

In case of 2 resistor units, power supply to transformers has to be taken from the same phases.<br />

2.3 Power cabling<br />

2.3.1 Shielded motor cable<br />

In crane application inverter fulfils EN61800-3/A11 (IEC 1800-3) second environment radiated emission<br />

requirements without shielded motor cable.<br />

In the second environment, shielded motor cable is recommended to use in fixed installations, especially<br />

in buildings. However motor cables in crane and festoon power supplies are normally not shielded due to<br />

the practical reasons.<br />

2.3.2 Double collectors<br />

If the power is supplied to the crane via conductor rails, double collectors are needed. This ensures a<br />

reliable contact with the rail in all circumstances. Short interruptions and sparks between the conductor<br />

rail and the collector may cause nuisance tripping, other undesired operations and in worst case even<br />

permanent damage to components.<br />

2.3.3 Cable selection<br />

Cabling for inverter can be done using normal crane cables. All the cables must be dimensioned<br />

according to local regulations. Ambient temperature, cabling method (size of bunches etc.) and allowable<br />

current for the cable in use must be taken into consideration. If there are no other regulations, following<br />

values can be used (three phase 400V supply).<br />

12/79<br />

This document and the information contained herein, is the exclusive property of R&M <strong>Materials</strong> <strong>Handling</strong> Inc. and represents a non-public, confidential and proprietary<br />

trade secret that may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M<br />

<strong>Materials</strong> <strong>Handling</strong> Inc. Copyright © (2005) R&M <strong>Materials</strong> <strong>Handling</strong> Inc. All rights reserved.