2DC<br />

Problem Causes Check procedures/corrective measures<br />

(13)<br />

Main charging is not<br />

performed.<br />

Broken main charger wire.<br />

Leaking main charger<br />

housing.<br />

Poor contact in the high<br />

voltage board connector<br />

terminals.<br />

Defective engine board<br />

(KP-5061).<br />

Defective high voltage<br />

board.<br />

See page 1-5-14.<br />

(14)<br />

Transfer charging is<br />

not performed.<br />

(15)<br />

A paper jam in the<br />

paper feed or exit<br />

section is indicated<br />

when the main<br />

switch is turned on.<br />

(16)<br />

The message requesting<br />

cover to be<br />

closed is displayed<br />

when the front cover<br />

is closed.<br />

(17)<br />

Others.<br />

Poor contact in the high<br />

voltage board connector<br />

terminals.<br />

Defective engine board<br />

(KP-5061).<br />

Defective high voltage<br />

board.<br />

A piece of paper torn from<br />

copy paper is caught<br />

around registration snsor<br />

or exit sensor.<br />

Defective registration sensor.<br />

Defective exit sensor.<br />

Poor contact in the connector<br />

terminals of interlock<br />

switch.<br />

Defective interlock switch.<br />

Wiring is broken, shorted<br />

or makes poor contact.<br />

Noise.<br />

See page 1-5-14.<br />

Check and remove if any.<br />

Run maintenance item U031 and turn registration sensor on and<br />

off manually. Replace registration sensor if indication of the corresponding<br />

sensor is not light.<br />

Run maintenance item U031 and turn exit sensor on and off<br />

manually. Replace exit sensor if indication of the corresponding<br />

sensor is not light.<br />

Reinsert the connector. Also check for continuity within the connector<br />

cable. If none, remedy or replace the cable.<br />

Check for continuity across switch. If there is no continuity when<br />

the switch is on, replace it.<br />

Check for continuity. If none, repair.<br />

Locate the source of noise and remove.<br />

1-5-22