2DC<br />

1-5-4 Electrical problems<br />

Problem Causes Check procedures/corrective measures<br />

(1)<br />

The machine does<br />

not operate when<br />

the main switch is<br />

turned on.<br />

No electricity at the power<br />

outlet.<br />

The power cord is not<br />

plugged in properly.<br />

The front cover is not<br />

closed completely.<br />

Measure the input voltage.<br />

Check the contact between the power plug and the outlet.<br />

Check the front cover.<br />

(2)<br />

The main motor<br />

does not operate<br />

(C2000).<br />

(3)<br />

The scanner motor<br />

does not operate.<br />

(4)<br />

Cooling fan does<br />

not operate.<br />

(5)<br />

The feed clutch<br />

does not operate.<br />

Broken power cord.<br />

Defective main switch.<br />

Blown fuse in the power<br />

supply board (KP-5059).<br />

Defective interlock switch.<br />

Defective power supply<br />

board (KP-5059).<br />

Poor contact in the main<br />

motor connector terminals.<br />

Broken main motor gear.<br />

Defective main motor.<br />

Defective engine board<br />

(KP-5061).<br />

Broken scanner motor coil.<br />

Poor contact in the scanner<br />

motor connector terminals.<br />

Broken Cooling fan coil.<br />

Poor contact in the Cooling<br />

fan connector terminals.<br />

Broken feed clutch coil.<br />

Poor contact in the feed<br />

clutch connector terminals.<br />

Defective engine board<br />

(KP-5061).<br />

Check for continuity. If none, replace the cord.<br />

Check for continuity across the contacts. If none, replace the<br />

main switch.<br />

Check for continuity. If none, remove the cause of blowing and<br />

replace the fuse.<br />

Check for continuity across the contacts of switch. If none, replace<br />

the switch.<br />

With AC present, check for 24 V DC at CN2-6 and 5 V DC at<br />

CN2-1 on the power supply board (KP-5059). If none, replace<br />

the power supply board (KP-5059).<br />

Reinsert the connector. Also check for continuity within the connector<br />

cable. If none, remedy or replace the cable.<br />

Check visually and replace the main motor if necessary.<br />

Run maintenance item U030 and check if the main motor operates<br />

and replace the main motor if necessary.<br />

Run maintenance item U030 and check if YC4-9 on the engine<br />

board (KP-5061) go low. If not, replace the engine board (KP-<br />

5061).<br />

Check for continuity across the coil. If none, replace the scanner<br />

motor.<br />

Reinsert the connector. Also check for continuity within the connector<br />

cable. If none, remedy or replace the cable.<br />

Check for continuity across the coil. If none, replace Cooling fan.<br />

Reinsert the connector. Also check for continuity within the connector<br />

cable. If none, remedy or replace the cable.<br />

Check for continuity across the coil. If none, replace the feed<br />

clutch.<br />

Reinsert the connector. Also check for continuity within the connector<br />

cable. If none, remedy or replace the cable.<br />

Run maintenance item U032 and check if YC4-1 on the engine<br />

board (KP-5061) goes low. If not, replace the engine board (KP-<br />

5061).<br />

1-5-20