2DC<br />

(1) No image appears<br />

(entirely white).<br />

Causes<br />

1. No transfer charging.<br />

Causes<br />

1. No transfer charging.<br />

A. The connector terminals of the high voltage<br />

board make poor contact.<br />

B. Defective engine board (KP-5061).<br />

C. Defective high voltage board.<br />

Check procedures/corrective measures<br />

Reinsert the connector. Also check for continuity within the<br />

connector cable. If none, remedy or replace the cable.<br />

Replace the engine board (KP-5061) and check for correct<br />

operation.<br />

Replace the high voltage board and check for correct operation.<br />

(2) No image appears<br />

(entirely black).<br />

Causes<br />

1. No main charging.<br />

2. Exposure lamp fails to light.<br />

Causes<br />

1. No main charging.<br />

A. Broken main charger wire.<br />

B. Leaking main charger housing.<br />

C. The connector terminals of the high voltage<br />

board make poor contact.<br />

D. Defective engine board (KP-5061).<br />

E. Defective high voltage board.<br />

2. Exposure lamp fails to light.<br />

A. The connector terminals of the exposure<br />

lamp make poor contact.<br />

B. Defective CCD board (KP-5065).<br />

C. Defective scanner board (KP-5063).<br />

D. Defective engine board (KP-5061).<br />

Check procedures/corrective measures<br />

Replace the process unit.<br />

Replace the process unit.<br />

Reinsert the connector. Also check for continuity within the<br />

connector cable. If none, remedy or replace the cable.<br />

Replace the engine board (KP-5061) and check for correct<br />

operation.<br />

Replace the high voltage board and check for correct operation.<br />

Reinsert the connector. Also check for continuity within the<br />

connector cable. If none, remedy or replace the cable.<br />

Replace the CCD board (KP-5065) and check for correct operation.<br />

Replace the scanner board (KP-5063) and check for correct<br />

operation.<br />

Replace the engine board (KP-5061) and check for correct<br />

operation.<br />

1-5-14