2DC<br />

Code<br />

Contents<br />

Causes<br />

Remarks<br />

Check procedures/corrective measures<br />

C3200<br />

(A3200*)<br />

Exposure lamp problem<br />

• In indicator check before starting<br />

copying, the average value in scanning<br />

of the shading plate with the<br />

CCD is 128 or more.<br />

Defective scanner<br />

board (KP-5063).<br />

Defective exposure<br />

lamp or inverter<br />

board.<br />

Replace the scanner board (KP-5063) and<br />

check for correct operation.<br />

Replace the exposure lamp or inverter<br />

board.<br />

Incorrect shading<br />

position.<br />

Adjust the position of the contact glass<br />

(shading plate). If the problem still occurs,<br />

replace the scanner home position sensor.<br />

Poor contact of<br />

the connector terminals.<br />

Check the connection of connector YC-6<br />

on the scanner board (KP-5063), and the<br />

continuity across the connector terminals.<br />

Repair or replace if necessary.<br />

C3300<br />

(A3300*)<br />

Optical system (AGC) problem<br />

• After AGC, correct input is not obtained<br />

at CCD.<br />

Insufficient exposure<br />

lamp luminosity.<br />

Replace the exposure lamp or inverter<br />

board.<br />

Defective scanner<br />

board (KP-5063).<br />

Replace the scanner board (KP-5063) and<br />

check for correct operation.<br />

Incorrect shading<br />

position.<br />

Adjust the position of the contact glass<br />

(shading plate). If the problem still occurs,<br />

replace the scanner home position sensor.<br />

C4000<br />

(A4000*)<br />

Polygon motor synchronization<br />

problem<br />

• The polygon motor does not reach<br />

the stable speed within 15 s of the<br />

START signal turning on.<br />

Poor contact in<br />

the polygon motor<br />

connector terminals.<br />

Defective polygon<br />

motor.<br />

Reinsert the connector. Also check for continuity<br />

within the connector cable. If none,<br />

remedy or replace the cable.<br />

Replace the LSU.<br />

Defective engine<br />

board (KP-5061).<br />

Replace the engine board (KP-5061) and<br />

check for correct operation.<br />

C4010<br />

(A4010*)<br />

Polygon motor steady-state problem<br />

• The polygon motor rotation is not<br />

stable for 5 s after the polygon motor<br />

rotation has been stabilized.<br />

Poor contact in<br />

the polygon motor<br />

connector terminals.<br />

Reinsert the connector. Also check for continuity<br />

within the connector cable. If none,<br />

remedy or replace the cable.<br />

Defective polygon<br />

motor.<br />

Replace the LSU.<br />

Defective engine<br />

board (KP-5061).<br />

Replace the engine board (KP-5061) and<br />

check for correct operation.<br />

C4200<br />

(A4200*)<br />

BD steady-state problem<br />

• The MIC detects a BD error for 600<br />

ms after the polygon motor rotation<br />

has been stabilized.<br />

Defective laser<br />

diode.<br />

Defective polygon<br />

motor.<br />

Replace the LSU.<br />

Replace the LSU.<br />

Defective main<br />

board (KP-5060).<br />

Replace the main board (KP-5060) and<br />

check for correct operation.<br />

“A” is displayed on the market.<br />

1-5-10