2DC<br />

1-5-2 Self-diagnosis<br />

(1) Self-diagnostic function<br />

This unit is equipped with a self-diagnostic function. When a problem is detected, copying is disabled. "C" and a number<br />

between 0100 and 7990 altenates, indicating the nature of the problem.<br />

After removing the problem, the self-diagnostic function can be reset by turning interolck switch off and back on.<br />

(2) Self diagnostic codes<br />

Code<br />

Contents<br />

Causes<br />

Remarks<br />

Check procedures/corrective measures<br />

C0100<br />

Backup memory read/write problem<br />

(main board (KP-5060))<br />

• Read and write data does not match.<br />

Defective backup<br />

RAM or main<br />

board (KP-5060).<br />

Replace the main board (KP-5060) and<br />

check for correct operation.<br />

C0110<br />

(A0110*)<br />

Backup memory data problem (main<br />

board (KP-5060))<br />

• Data in the specified area of the<br />

backup memory does not match the<br />

specified values.<br />

Problem with the<br />

backup memory<br />

data.<br />

Defective backup<br />

RAM.<br />

Turn interlock switch off and back on and<br />

run maintenance item U020 to set the contents<br />

of the backup memory data again.<br />

If the C0110 is displayed after re-setting<br />

the backup memory contents, replace the<br />

backup RAM or main board (KP-5060).<br />

C0150<br />

Backup memory read/write problem<br />

(engine board (KP-5061))<br />

• Read and write data does not match.<br />

Defective backup<br />

RAM or engine<br />

board (KP-5061).<br />

Replace the engine board (KP-5061) and<br />

check for correct operation.<br />

C0160<br />

(A0160*)<br />

Backup memory data problem (engine<br />

board (KP-5061))<br />

• Data in the specified area of the<br />

backup memory does not match the<br />

specified values.<br />

Problem with the<br />

backup memory<br />

data.<br />

Defective backup<br />

RAM.<br />

Turn interlock switch off and back on and<br />

run maintenance item U020 to set the contents<br />

of the backup memory data again.<br />

If the C0160 is displayed after re-setting<br />

the backup memory contents, replace the<br />

backup RAM or engine board (KP-5061).<br />

C0170<br />

Accounting count problem<br />

• When the power is turned on, the total<br />

count and the scan count are abnormal<br />

both on the main board (KP-<br />

5060) and the engine board<br />

(KP-5061).<br />

Defective main<br />

board (KP-5060)<br />

or engine board<br />

(KP-5061).<br />

Replace the main board (KP-5060) or engine<br />

board (KP-5061) and check for correct<br />

operation.<br />

C0180<br />

Machine number mismatch<br />

• When the power is turned on, the machine<br />

number does not match between<br />

the main board (KP-5060) and<br />

the engine board (KP-5061).<br />

Defective main<br />

board (KP-5060)<br />

or engine board<br />

(KP-5061).<br />

Replace the main board (KP-5060) or engine<br />

board (KP-5061) and check for correct<br />

operation.<br />

C0210<br />

(A0210*)<br />

Communication problem between<br />

the main board (KP-5060) and engine<br />

board (KP-5061)<br />

• When the power is turned on, the machine<br />

does not detect the low level of<br />

SBSY and the high level of SDIR for<br />

three seconds.<br />

Poor contact in<br />

the connector terminals.<br />

Defective main<br />

board (KP-5060)<br />

or engine board<br />

(KP-5061).<br />

Check the connection of connectors YC3<br />

on the main board (KP-5060) and YC3 on<br />

the engine board (KP-5061), and the continuity<br />

across the connector terminals. Repair<br />

or replace if necessary.<br />

Replace the main board (KP-5060) or engine<br />

board (KP-5061) and check for correct<br />

operation.<br />

“A” is displayed on the market.<br />

1-5-8