2DC<br />

Maintenance<br />

item No.<br />

U162<br />

U163<br />

U199<br />

U200<br />

Description<br />

Stabilizing fixing forcibly<br />

Description<br />

Stops the stabilization fixing drive forcibly, regardless of fixing temperature.<br />

Purpose<br />

To forcibly stabilize the machine before the fixing section reaches stabilization temperature.<br />

Method<br />

1. Press the start key. “on” appears.<br />

2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regardless<br />

of fixing temperature. The indication for selecting a maintenance item No. appears.<br />

To exit the forced stabilization mode, turn the power off and on.<br />

Completion<br />

Press the stop/clear key. The indication for selecting a maintenance item No. appears.<br />

Resetting the fixing problem data<br />

Description<br />

Resets the detection of a service call code indicating a problem in the fixing section.<br />

Purpose<br />

To prevent accidents due to an abnormally high fixing temperature.<br />

Method<br />

1. Press the start key. “CLE” appears.<br />

2. Press the start key. The fixing problem data is initialized.<br />

Completion<br />

Press the stop/clear key. The indication for selecting a maintenance item No. appears.<br />

Checking the fixing temperature<br />

Description<br />

Displays the fixing temperature and the ambient temperature.<br />

Purpose<br />

To check the fixing temperature and the ambient temperature.<br />

Method<br />

1. Press the start key.<br />

2. Display each temperature by lighting the respective copy exposure indicator using the copy exposure<br />

adjustment keys.<br />

Copy exposure indicator Description<br />

Exp. 1<br />

Fixing temperature (°C)<br />

Exp. 2<br />

Ambient temperature (°C)<br />

Completion<br />

Press the stop/clear key. The indication for selecting a maintenance item No. appears.<br />

Turning all LEDs on<br />

Description<br />

Turns all the LEDs on the operation panel on.<br />

Purpose<br />

To check if all the LEDs on the operation panel light.<br />

Method<br />

Press the start key. All the LEDs on the operation panel light.<br />

Press the stop/clear key or wait for 10 s. The LEDs turns off, and the indication for selecting a maintenance item<br />

No. appears.<br />

1-4-19