2DC<br />

Maintenance<br />

Description<br />

item No.<br />

U020 Initializing all data<br />

Description<br />

Initializes all the backup RAM on the main board to return to the original settings. U004, however, is not<br />

initialized.<br />

Purpose<br />

Run as needed.<br />

Method<br />

1. Press the start key.<br />

2. Select “on” using the zoom +/– keys.<br />

Display<br />

Operation<br />

– – – Canceling initialization<br />

on<br />

Executing initialization<br />

3. Press the start key. All data in the backup RAM is initialized, and the original settings for EUROPE<br />

specifications are set.<br />

When initialization is complete, the machine automatically returns to the same status as when the main<br />

switch is turned on.<br />

Completion<br />

To exit this maintenance item without executing initialization, press the stop/clear key. The indication for<br />

selecting a maintenance item No. appears.<br />

U021 Initializing memories<br />

Description<br />

Initializes the setting data other than that for adjustments due to variations between respective machines, i.e.,<br />

settings for counters, service call history and mode settings. As a result, initializes the backup RAM according<br />

to the specifications depending on the destination selected in U252. U004, however, is not initialized.<br />

Purpose<br />

Used to return the machine settings to the factory settings.<br />

Method<br />

1. Press the start key.<br />

2. Select “on” using the zoom +/– keys.<br />

Display<br />

Operation<br />

– – – Canceling initialization<br />

on<br />

Executing initialization<br />

3. Press the start key. All data other than that for adjustments due to variations between machines is<br />

initialized based on the destination setting. When initialization is complete, the machine automatically<br />

returns to the same status as when the main switch is turned on.<br />

Completion<br />

To exit this maintenance item without executing initialization, press the stop/clear key. The indication for<br />

selecting a maintenance item No. appears.<br />