2DC<br />

Section<br />

Fixing and<br />

cleaning<br />

Operation<br />

panel and<br />

support<br />

equipment<br />

Mode setting<br />

Image<br />

processing<br />

Others<br />

Item<br />

Initial<br />

Maintenance item contents<br />

No.<br />

setting*<br />

U161 Setting the fixing control temperature<br />

• Primary stabilization fixing temperature 125<br />

• Secondary stabilization fixing temperature 135<br />

• Copying operation temperature 1 180<br />

• Copying operation temperature 2 195<br />

• Number of sheets for fixing control 5<br />

U162 Stabilizing fixing forcibly —<br />

U163 Resetting the fixing problem data —<br />

U199 Checking the fixing temperature —<br />

U200 Turning all LEDs on —<br />

U203 Operating DP separately —<br />

U207 Checking the operation panel keys —<br />

U243 Checking the operation of the DP motors —<br />

U244 Checking the DP switches —<br />

U252 Setting the destination Europe<br />

U254 Turning auto start function on/off On<br />

U255 Setting auto clear time 90<br />

U258 Switching copy operation at toner empty detection Single mode<br />

U260 Changing the copy count timing After ejection<br />

U265 Setting the destination specifications 0<br />

U332 Setting the size conversion factor 1.0<br />

U342 Setting the ejection restriction On<br />

U402 Adjusting margins for printing —<br />

U403 Adjusting margins for scanning an original on the contact glass —<br />

U404 Adjusting margins for scanning an original from the DP —<br />

U901 Checking/clearing copy counts by paper feed locations —<br />

U903 Checking/clearing the paper jam counts —<br />

U904 Checking/clearing the service call counts —<br />

U905 Checking/clearing counts by the DP —<br />

U908 Checking the total count —<br />

U910 Clearing the black ratio data —<br />

U911 Checking/clearing copy counts by paper size —<br />

U927 Clearing accounting counter —<br />

U990 Checking/clearing the time for the exposure lamp to light —<br />

U991 Checking the scanner count —<br />

U993 Outputting a VTC-PG pattern —<br />

* Initial setting for executing maintenance item U020<br />